MX-160 — 5 off for the Charlotte plant
Samuel Arroyos.arroyo@cascadefoods.example·Email · Sep 19, 9:00 AMMX-160 — 5 off for the Charlotte plantMorning, Could you price up 5 off MX-160 for us? Same as the units on the glycol skid — 316 stainless, ATEX Zone 1 area, 460V 3ph, DN50 connections, running around 35 m3/h at 90 C. No great rush but I'd like them on site inside the month.
Read messageHide
Morning, Could you price up 5 off MX-160 for us? Same as the units on the glycol skid — 316 stainless, ATEX Zone 1 area, 460V 3ph, DN50 connections, running around 35 m3/h at 90 C. No great rush but I'd like them on site inside the month.
Flow rate≥ 35 m³/hStated
Written in the customer's message
“Morning, Could you price up 5 off MX-160 for us? Same as the units on the glycol skid — 316 stainless, ATEX Zone 1 area, 460V 3ph, DN50 connections, running around 35 m3/h at 90 C.”
Fluid temperature≥ 90 °CStated
Written in the customer's message
“Morning, Could you price up 5 off MX-160 for us? Same as the units on the glycol skid — 316 stainless, ATEX Zone 1 area, 460V 3ph, DN50 connections, running around 35 m3/h at 90 C.”
Pump must be rated at or above this fluid temperature.
Hazardous area ratingATEX Zone 1Stated
Written in the customer's message
“Morning, Could you price up 5 off MX-160 for us? Same as the units on the glycol skid — 316 stainless, ATEX Zone 1 area, 460V 3ph, DN50 connections, running around 35 m3/h at 90 C.”
Area classification is a regulatory requirement and cannot be traded off.
Pipe connectionDN50Stated
Written in the customer's message
“Morning, Could you price up 5 off MX-160 for us? Same as the units on the glycol skid — 316 stainless, ATEX Zone 1 area, 460V 3ph, DN50 connections, running around 35 m3/h at 90 C.”
Quantity5 unitsStated
Written in the customer's message
“MX-160 — 5 off for the Charlotte plant.”
Referenced partMX-160Stated
Written in the customer's message
“MX-160 — 5 off for the Charlotte plant.”
Part number named in the request; used as the reference for inferred requirements.
Ship-to locationCharlotte processing plantStated
Written in the customer's message
“charlotte”
Supply voltage460 V 3phStated
Written in the customer's message
“Morning, Could you price up 5 off MX-160 for us? Same as the units on the glycol skid — 316 stainless, ATEX Zone 1 area, 460V 3ph, DN50 connections, running around 35 m3/h at 90 C.”
Wetted material316 stainless steelStated
Written in the customer's message
“Morning, Could you price up 5 off MX-160 for us? Same as the units on the glycol skid — 316 stainless, ATEX Zone 1 area, 460V 3ph, DN50 connections, running around 35 m3/h at 90 C.”
Installed footprint≈ 760 mmInferred
Derived from the part the customer already runs
“Currently running MX-160”
Replacement should sit within the MX-160 footprint (760 mm) to reuse the existing baseplate.
75% confidence
Required byNot statedMissing
Not present in the request
No delivery date or window is stated. Availability is assessed against stock only.
Technical validation
Every value compared by the rule engine, with the data-sheet section it came from. A hard failure rules a part out; no model can override it.
Requirement | Recommended MX-160Recommended | Alternative MX-180Viable | Alternative AX-200Rejected | Alternative AX-220Rejected | Alternative PX-400Rejected |
|---|---|---|---|---|---|
Pipe connection Needs DN50 Hard requirement | ANSI 150# flange DN50 2in DS-1026 §3.1 | ANSI 150# flange DN50 2in DS-1027 §3.1 | ANSI 150# flange DN50 2in DS-1001 §3.1 | ANSI 150# flange DN50 2in DS-1002 §3.1 | ANSI 150# flange DN50 2in DS-1017 §3.1 |
Installed footprint Needs 760 mm Soft · warns, does not block | 760 mm DS-1026 §5.1 | 820 mm DS-1027 §5.1 | 780 mm DS-1001 §5.1 | 840 mm DS-1002 §5.1 | 810 mm DS-1017 §5.1 |
Flow rate Needs at least 35 m³/h Hard requirement | 35 m³/h DS-1026 §2.2 | 55 m³/h DS-1027 §2.2 | 40 m³/h DS-1001 §2.2 | 60 m³/h DS-1002 §2.2 | 35 m³/h DS-1017 §2.2 |
Hazardous area rating Needs ATEX Zone 1 Hard requirement | ATEX II 2G Zone 1 DS-1026 §4.1 | ATEX II 2G Zone 1 DS-1027 §4.1 | None — general purpose DS-1001 §4.1 | None — general purpose DS-1002 §4.1 | None — general purpose DS-1017 §4.1 |
Wetted material Needs 316 stainless steel Hard requirement | 316 stainless steel DS-1026 §3.1 | 316 stainless steel DS-1027 §3.1 | 316 stainless steel DS-1001 §3.1 | 316 stainless steel DS-1002 §3.1 | 316 stainless steel DS-1017 §3.1 |
Fluid temperature Needs at least 90 °C Hard requirement | 140 °C DS-1026 §2.1 | 150 °C DS-1027 §2.1 | 120 °C DS-1001 §2.1 | 120 °C DS-1002 §2.1 | 190 °C DS-1017 §2.1 |
Supply voltage Needs 460 V 3ph Hard requirement | 460 V 3ph 60 Hz DS-1026 §3.2 | 460 V 3ph 60 Hz DS-1027 §3.2 | 460 V 3ph 60 Hz DS-1001 §3.2 | 460 V 3ph 60 Hz DS-1002 §3.2 | 460 V 3ph 60 Hz DS-1017 §3.2 |
5 more parts were screened and ruled out
- PX-422Hazardous area rating None — general purpose — needs ATEX Zone 1PX-422 high-temperature process pump, 195 °C
- PX-440Hazardous area rating None — general purpose — needs ATEX Zone 1PX-440 high-temperature process pump, 205 °C
- PX-460Hazardous area rating ATEX II 3G Zone 2 — needs ATEX Zone 1PX-460 high-temperature process pump, 230 °C
- PX-480Pipe connection ANSI 150# flange DN80 3in — needs DN50PX-480 high-temperature process pump, 300 °C
- PX-500Pipe connection ANSI 150# flange DN100 4in — needs DN50PX-500 high-temperature process pump, 350 °C
Evidence
7 claims behind the decision, each tied to a section of a document in the technical library. Open one to read the source.
MX-160 pipe connection: ANSI 150# flange DN50 2in.DS-1026 §3.1
MX-160 product data sheet · §3.1 Mechanical constructionOpen in libraryInlet connection: ANSI 150# flange DN50 2in Outlet connection: ANSI 150# flange DN50 2in Wetted material: 316 stainless steel Seal / elastomer: Sealless — magnetic coupling, no dynamic seal Bearing arrangement: Product-lubricated silicon carbide Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
Supports: MX-160 pipe connection: ANSI 150# flange DN50 2in.
MX-160 installed footprint: 760 mm.DS-1026 §5.1
MX-160 product data sheet · §5.1 Dimensions and weightOpen in libraryOverall length: 760 mm Overall width: 334 mm Overall height: 395 mm Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
Supports: MX-160 installed footprint: 760 mm.
MX-160 flow rate: 35 m³/h.DS-1026 §2.2
MX-160 product data sheet · §2.2 Hydraulic performanceOpen in libraryMax flow rate: 35 m³/h Max head: 40 m NPSH required: 3.8 m Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
Supports: MX-160 flow rate: 35 m³/h.
MX-160 hazardous area rating: ATEX II 2G Zone 1.DS-1026 §4.1
MX-160 product data sheet · §4.1 Certification and area classificationOpen in libraryDuty: Continuous Hazardous area rating: ATEX II 2G Zone 1 Certifications: CE, ATEX 2014/34/EU, UL 778 Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
Supports: MX-160 hazardous area rating: ATEX II 2G Zone 1.
MX-160 wetted material: 316 stainless steel.DS-1026 §3.1
MX-160 product data sheet · §3.1 Mechanical constructionOpen in libraryInlet connection: ANSI 150# flange DN50 2in Outlet connection: ANSI 150# flange DN50 2in Wetted material: 316 stainless steel Seal / elastomer: Sealless — magnetic coupling, no dynamic seal Bearing arrangement: Product-lubricated silicon carbide Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
Supports: MX-160 wetted material: 316 stainless steel.
MX-160 fluid temperature: 140 °C.DS-1026 §2.1
MX-160 product data sheet · §2.1 Process limitsOpen in libraryMax fluid temperature: 140 °C Min fluid temperature: -30 °C Max discharge pressure: 14 bar Max viscosity: 150 cP Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
Supports: MX-160 fluid temperature: 140 °C.
MX-160 supply voltage: 460 V 3ph 60 Hz.DS-1026 §3.2
MX-160 product data sheet · §3.2 Electrical supply and motorOpen in librarySupply voltage: 460 V 3ph 60 Hz Ingress protection: IP55 Motor rating: 5.5 kW Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
Supports: MX-160 supply voltage: 460 V 3ph 60 Hz.
Fulfillment
Available-to-promise is on-hand stock less what is already reserved for other orders.
Commercials
Quote QT-2026-1041 · valid until Oct 22, 2026
| Part | Qty | List | Discount | Unit price | Price source | Extended |
|---|---|---|---|---|---|---|
| MX-160 MX-160 magnetic-drive sealless pump, 35 m³/h | 5 | $8,900.00 | 8.0% | $8,188.00 | Price Book | $40,940.00 |
- Subtotal at list
- $44,500.00
- Customer discount
- −$3,560.00
- Net goods
- $40,940.00
- Freight · Ground
- $369.20
- Cost of goods
- $26,700.00
- Freight, billed at cost
- $369.20
- Gross margin
- $14,240.00
Repricing is switched off. This public demo is read-only, so every visitor sees the same data. Clone the repository to use this — it works locally.
Customer response
Customer response
Draft v1 · generated from the case's computed facts, not yet edited
Agent activity
Each step is a recorded tool call, in the order it ran. The sentence is what the tool reported at the time — not a summary written afterwards.
Audit trail6 events · append-only
Audit trail
Append-only. What happened, when, and who caused it.
- Sep 22, 11:21 PM
Request received by email from Samuel Arroyo at Cascade Foods.
Samuel Arroyo
- Sep 22, 11:21 PM
Assigned to Marcus Oyelaran.
Routing
- Sep 22, 11:21 PM
Analysis started using the deterministic local provider.
Sales Engine
- Sep 22, 11:21 PM
5 × MX-160 as requested, available from stock
Sales Engine
- Sep 22, 11:21 PM
Quote QT-2026-1041 released for $41,309.20. Released without approval — every policy check was inside limits.
Sales Engine
- Sep 22, 11:21 PM
Customer-facing response drafted from the approved quote.
Sales Engine