Installation guide: split-shipment orders and site receiving

IG-9044Installation GuideRev A · published Jul 24, 2026· applies to AX Series, PX Series, VS Series

Practical notes when an order is filled from more than one distribution centre.

§1.0

Matched serial batches

Pumps shipped from different distribution centres may come from different production batches. For a multi-pump installation on a common header this is normally immaterial, but where pumps are to run in parallel on a shared duty, confirm that impeller trim is identical across the batches — a trim difference of a few millimetres produces uneven load sharing.
§2.0

Receiving and commissioning

Split shipments arrive on separate deliveries and often on different days. Where the site plans a single commissioning window, the estimated arrival of the later leg — not the earlier — is the date that governs. Quote the later date to the customer.