VS-230 product data sheet
Published performance, construction and certification limits for the VS-230.
§1.1
Scope and intended service
VS-230 vertical inline pump, 70 m³/h. Close-coupled vertical inline pump. Suction and discharge on a common centre line so it drops into a straight pipe run without a baseplate. This data sheet states the published limits for the VS-230. Selection outside these limits requires written application-engineering approval.
§2.1
Process limits
Max fluid temperature: 140 °C
Min fluid temperature: -10 °C
Max discharge pressure: 16 bar
Max viscosity: 150 cP
Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§2.2
Hydraulic performance
Max flow rate: 70 m³/h
Max head: 48 m
NPSH required: 2.9 m
Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§3.1
Mechanical construction
Inlet connection: ANSI 150# flange DN80 3in
Outlet connection: ANSI 150# flange DN80 3in
Wetted material: 316 stainless steel
Seal / elastomer: Single cartridge mechanical seal, carbon/SiC, EPDM elastomer
Bearing arrangement: Motor bearings, no separate bearing frame
Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§3.2
Electrical supply and motor
Supply voltage: 460 V 3ph 60 Hz
Ingress protection: IP55
Motor rating: 11 kW
Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§4.1
Certification and area classification
Duty: Continuous
Hazardous area rating: None — general purpose
Certifications: CE, UL 778
Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§5.1
Dimensions and weight
Overall length: 323 mm
Overall width: 323 mm
Overall height: 950 mm
Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§6.1
Ordering and lead time
Standard factory lead time for the VS-230 is 24 calendar days from order acknowledgement when stock is not available. Lifecycle status at this revision: active.
Synthetic documentation created for this demonstration. It does not describe a real product.