RG-100 product data sheet

DS-1031Spec SheetRev C · published Sep 22, 2026· applies to RG-100

Published performance, construction and certification limits for the RG-100.

§1.1

Scope and intended service

RG-100 internal gear pump, 28 m³/h. Internal gear pump for viscous media up to 80,000 cP. 316 stainless steel construction with hardened rotor and idler. This data sheet states the published limits for the RG-100. Selection outside these limits requires written application-engineering approval.
§2.1

Process limits

Max fluid temperature: 200 °C Min fluid temperature: -10 °C Max discharge pressure: 16 bar Max viscosity: 80,000 cP Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§2.2

Hydraulic performance

Max flow rate: 28 m³/h Max head: 163 m NPSH required: 2.2 m Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§3.1

Mechanical construction

Inlet connection: ANSI 150# flange DN40 1.5in Outlet connection: ANSI 150# flange DN40 1.5in Wetted material: 316 stainless steel Seal / elastomer: Single mechanical seal, carbon/SiC, FKM elastomer Bearing arrangement: Bronze journal, product lubricated Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§3.2

Electrical supply and motor

Supply voltage: 460 V 3ph 60 Hz Ingress protection: IP55 Motor rating: 5.5 kW Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§4.1

Certification and area classification

Duty: Continuous Hazardous area rating: None — general purpose Certifications: CE, UL 778 Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§5.1

Dimensions and weight

Overall length: 700 mm Overall width: 322 mm Overall height: 406 mm Values are continuous ratings at the published reference conditions. Intermittent excursions are not covered by this data sheet.
§6.1

Ordering and lead time

Standard factory lead time for the RG-100 is 60 calendar days from order acknowledgement when stock is not available. Lifecycle status at this revision: discontinued.

Synthetic documentation created for this demonstration. It does not describe a real product.